LibreNMS Discovery SQL[select `migration` from `migrations` order by `id` desc limit 1 [] 0.31ms] SQL[select count(*) as aggregate from `migrations` [] 0.25ms] SQL[select version() [] 0.17ms] =========================================== Component | Version --------- | ------- LibreNMS | 25.6.0 (2025-06-16T06:55:12-05:00) DB Schema | 2025_06_11_025425_hr_device_table_add_status_default (343) PHP | 8.3.19 Python | 3.9.21 Database | MariaDB 11.8.2-MariaDB RRDTool | 1.7.2 SNMP | 5.9.1 =========================================== DEBUG! LibreNMS config cache cleared and config reloaded. SQL[select `config_name`, `config_value` from `config` [] 0.5ms] SQL[select * from `graph_types` [] 0.2ms] SQL[select * from `config` where (`config_name` = ?) limit 1 ["fping6"] 0.26ms] SQL[delete from `config` where `config_name` like ? ["fping6.%"] 0.17ms] 192.168.149.111 55 ribbon SQL[select * from `devices` where `device_id` = ? limit 1 [55] 0.27ms] SQL[select * from `devices_attribs` where `devices_attribs`.`device_id` = ? and `devices_attribs`.`device_id` is not null [55] 0.2ms] [FPING] '/usr/sbin/fping' '-4' '-e' '-q' '-c' '3' '-p' '500' '-t' '500' '-O' '0' '192.168.149.111' response: 192.168.149.111 : xmt/rcv/%loss = 3/3/0%, min/avg/max = 2.84/2.92/2.97 SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Pu' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0'] SNMPv2-MIB::sysObjectID.0 = SNMPv2-SMI::enterprises.12*.1.19 Modules status: Global+ OS Device #### Load disco module core #### Attempting to initialize OS: ribbon Attempting to initialize Group OS: network OS initialized as Generic (ribbon) SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Pu' '-On' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0' 'SNMPv2-MIB::sysDescr.0' 'SNMPv2-MIB::sysName.0'] .*.*.0 = .*.4.1.12*.1.19 .*.*.0 = Ribbon Communications. NPT-2100A, V9.1.00411-07, Build Date: Wed Dec 27 01:25:44 2023. Copyright (c) 2000-2021 Ribbon Communica .*.*.0 = AYRS-NPT2100-A | Ribbon Communications. NPT-2100A, V9.1.00411-07, Build Date: Wed Dec 27 01:25:44 2023. Copyright (c) 2000-2021 Ribbon Communica | .1.3.6.1.4.1.1286.5.1.1.1.19 | OS: Ribbon Neptune (ribbon) Attempting to initialize OS: ribbon Attempting to initialize Group OS: network OS initialized as Generic (ribbon) >> Runtime for discovery module 'core': 0.0170 seconds with 10440 bytes >> SNMP: [1/0.01s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module core #### Modules status: Global+ OS Device #### Load disco module os #### Yaml location data: SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysLocation.0'] Hz SQL[select * from `locations` where (`location` = ?) limit 1 ["Hz"] 0.28ms] ::query() failed: DNS request failed: The domain name referenced in the query does not exist. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'sysContact.0'] ecitele.com Yaml OS data: Location: Hz Hardware: OS Version: OS Features: Serial: >> Runtime for discovery module 'os': 0.0990 seconds with 122936 bytes >> SNMP: [4/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module os #### Modules status: Global+ OS Device #### Load disco module ports #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifDescr'] ifDescr.3 = et-bs/0 ifDescr.4 = et-bs/1 ifDescr.5 = et-bs/27 ifDescr.7 = et-bs/15 ifDescr.8 = et-bs/16 ifDescr.4194311 = et-bs/0 ifDescr.4194312 = et-bs/1 ifDescr.4194313 = et-bs/27 ifDescr.4194316 = et-bs/15 ifDescr.4194317 = et-bs/16 ifDescr.8388609 = lo0.0 ifDescr.8388610 = et-bs/0.0 ifDescr.8388611 = et-bs/1.0 ifDescr.8388612 = et-bs/27.0 ifDescr.8388613 = et-bs/16.0 ifDescr.8388614 = et-bs/16.1 ifDescr.8388615 = et-bs/16.2 ifDescr.8388616 = et-bs/15.0 SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifName'] ifName.3 = et-bs/0 ifName.4 = et-bs/1 ifName.5 = et-bs/27 ifName.7 = et-bs/15 ifName.8 = et-bs/16 ifName.4194311 = et-bs/0 ifName.4194312 = et-bs/1 ifName.4194313 = et-bs/27 ifName.4194316 = et-bs/15 ifName.4194317 = et-bs/16 ifName.8388609 = lo0.0 ifName.8388610 = et-bs/0.0 ifName.8388611 = et-bs/1.0 ifName.8388612 = et-bs/27.0 ifName.8388613 = et-bs/16.0 ifName.8388614 = et-bs/16.1 ifName.8388615 = et-bs/16.2 ifName.8388616 = et-bs/15.0 SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifAlias'] ifAlias.3 = ifAlias.4 = ifAlias.5 = ifAlias.7 = ifAlias.8 = VZW KFGS/53175 - Emmetsburg ifAlias.4194311 = WEBB-2300-B ifAlias.4194312 = AYRS-2100-B ifAlias.4194313 = ifAlias.4194316 = ifAlias.4194317 = ifAlias.8388609 = ifAlias.8388610 = ifAlias.8388611 = ifAlias.8388612 = ifAlias.8388613 = NCN0242/Emmetsburg_VZW/VLAN_53256_1420 ifAlias.8388614 = NCN1189_VZW_AYR_EMMETSBURG/VLAN_53176_1413 ifAlias.8388615 = NCN1190_VZW_AYR_EMMETSBURG/VLAN_53177_1414 ifAlias.8388616 = NCN1139_Ayrshire_EM_WAN_140 SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifType'] ifType.3 = ethernetCsmacd ifType.4 = ethernetCsmacd ifType.5 = ethernetCsmacd ifType.7 = ethernetCsmacd ifType.8 = ethernetCsmacd ifType.4194311 = other ifType.4194312 = other ifType.4194313 = other ifType.4194316 = other ifType.4194317 = other ifType.8388609 = other ifType.8388610 = other ifType.8388611 = other ifType.8388612 = other ifType.8388613 = other ifType.8388614 = other ifType.8388615 = other ifType.8388616 = other SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifOperStatus'] ifOperStatus.3 = up ifOperStatus.4 = up ifOperStatus.5 = up ifOperStatus.7 = up ifOperStatus.8 = up ifOperStatus.4194311 = up ifOperStatus.4194312 = up ifOperStatus.4194313 = up ifOperStatus.4194316 = up ifOperStatus.4194317 = up ifOperStatus.8388609 = up ifOperStatus.8388610 = up ifOperStatus.8388611 = up ifOperStatus.8388612 = up ifOperStatus.8388613 = up ifOperStatus.8388614 = up ifOperStatus.8388615 = up ifOperStatus.8388616 = up array ( 3 => array ( 'ifDescr' => 'et-bs/0', 'ifName' => 'et-bs/0', 'ifAlias' => '', 'ifType' => 'ethernetCsmacd', 'ifOperStatus' => 'up', ), 4 => array ( 'ifDescr' => 'et-bs/1', 'ifName' => 'et-bs/1', 'ifAlias' => '', 'ifType' => 'ethernetCsmacd', 'ifOperStatus' => 'up', ), 5 => array ( 'ifDescr' => 'et-bs/27', 'ifName' => 'et-bs/27', 'ifAlias' => '', 'ifType' => 'ethernetCsmacd', 'ifOperStatus' => 'up', ), 7 => array ( 'ifDescr' => 'et-bs/15', 'ifName' => 'et-bs/15', 'ifAlias' => '', 'ifType' => 'ethernetCsmacd', 'ifOperStatus' => 'up', ), 8 => array ( 'ifDescr' => 'et-bs/16', 'ifName' => 'et-bs/16', 'ifAlias' => 'VZW KFGS/53175 - Emmetsburg', 'ifType' => 'ethernetCsmacd', 'ifOperStatus' => 'up', ), 4194311 => array ( 'ifDescr' => 'et-bs/0', 'ifName' => 'et-bs/0', 'ifAlias' => 'WEBB-2300-B', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 4194312 => array ( 'ifDescr' => 'et-bs/1', 'ifName' => 'et-bs/1', 'ifAlias' => 'AYRS-2100-B', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 4194313 => array ( 'ifDescr' => 'et-bs/27', 'ifName' => 'et-bs/27', 'ifAlias' => '', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 4194316 => array ( 'ifDescr' => 'et-bs/15', 'ifName' => 'et-bs/15', 'ifAlias' => '', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 4194317 => array ( 'ifDescr' => 'et-bs/16', 'ifName' => 'et-bs/16', 'ifAlias' => '', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 8388609 => array ( 'ifDescr' => 'lo0.0', 'ifName' => 'lo0.0', 'ifAlias' => '', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 8388610 => array ( 'ifDescr' => 'et-bs/0.0', 'ifName' => 'et-bs/0.0', 'ifAlias' => '', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 8388611 => array ( 'ifDescr' => 'et-bs/1.0', 'ifName' => 'et-bs/1.0', 'ifAlias' => '', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 8388612 => array ( 'ifDescr' => 'et-bs/27.0', 'ifName' => 'et-bs/27.0', 'ifAlias' => '', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 8388613 => array ( 'ifDescr' => 'et-bs/16.0', 'ifName' => 'et-bs/16.0', 'ifAlias' => 'NCN0242/Emmetsburg_VZW/VLAN_53256_1420', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 8388614 => array ( 'ifDescr' => 'et-bs/16.1', 'ifName' => 'et-bs/16.1', 'ifAlias' => 'NCN1189_VZW_AYR_EMMETSBURG/VLAN_53176_1413', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 8388615 => array ( 'ifDescr' => 'et-bs/16.2', 'ifName' => 'et-bs/16.2', 'ifAlias' => 'NCN1190_VZW_AYR_EMMETSBURG/VLAN_53177_1414', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 8388616 => array ( 'ifDescr' => 'et-bs/15.0', 'ifName' => 'et-bs/15.0', 'ifAlias' => 'NCN1139_Ayrshire_EM_WAN_140', 'ifType' => 'other', 'ifOperStatus' => 'up', ), ) Using ifDescr as ifAlias SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/0","et-bs\/0","et-bs\/0","ethernetCsmacd","up",3,747324] 0.21ms] . Using ifDescr as ifAlias SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/1","et-bs\/1","et-bs\/1","ethernetCsmacd","up",4,747325] 0.15ms] . Using ifDescr as ifAlias SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/27","et-bs\/27","et-bs\/27","ethernetCsmacd","up",5,747326] 0.13ms] . Using ifDescr as ifAlias SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/15","et-bs\/15","et-bs\/15","ethernetCsmacd","up",7,747926] 0.13ms] .SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/16","et-bs\/16","VZW KFGS\/53175 - Emmetsburg","ethernetCsmacd","up",8,747931] 0.14ms] .SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/0","et-bs\/0","WEBB-2300-B","other","up",4194311,747327] 0.23ms] .SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/1","et-bs\/1","AYRS-2100-B","other","up",4194312,747328] 0.17ms] . Using ifDescr as ifAlias SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/27","et-bs\/27","et-bs\/27","other","up",4194313,747329] 0.14ms] . Using ifDescr as ifAlias SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/15","et-bs\/15","et-bs\/15","other","up",4194316,747928] 0.13ms] . Using ifDescr as ifAlias SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/16","et-bs\/16","et-bs\/16","other","up",4194317,747932] 0.14ms] . Using ifDescr as ifAlias SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["lo0.0","lo0.0","lo0.0","other","up",8388609,747330] 0.14ms] . Using ifDescr as ifAlias SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/0.0","et-bs\/0.0","et-bs\/0.0","other","up",8388610,747331] 0.14ms] . Using ifDescr as ifAlias SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/1.0","et-bs\/1.0","et-bs\/1.0","other","up",8388611,747332] 0.14ms] . Using ifDescr as ifAlias SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/27.0","et-bs\/27.0","et-bs\/27.0","other","up",8388612,747333] 0.13ms] .SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/16.0","et-bs\/16.0","NCN0242\/Emmetsburg_VZW\/VLAN_53256_1420","other","up",8388613,747933] 0.12ms] .SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/16.1","et-bs\/16.1","NCN1189_VZW_AYR_EMMETSBURG\/VLAN_53176_1413","other","up",8388614,747936] 0.13ms] .SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/16.2","et-bs\/16.2","NCN1190_VZW_AYR_EMMETSBURG\/VLAN_53177_1414","other","up",8388615,747941] 0.13ms] .SQL[UPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? ["et-bs\/15.0","et-bs\/15.0","NCN1139_Ayrshire_EM_WAN_140","other","up",8388616,747942] 0.15ms] . >> Runtime for discovery module 'ports': 0.0970 seconds with 31992 bytes >> SNMP: [5/0.09s] MySQL: [18/0.03s] RRD: [0/0.00s] #### Unload disco module ports #### Modules status: Global+ OS Device #### Load disco module ports-stack #### SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUt' '-Pu' 'udp:HOSTNAME:161' 'IF-MIB::ifStackStatus'] IF-MIB::ifStackStatus = No Such Object available on this agent at this OID SNMP query failed. Exit Code: 0 Empty: false Bad String: No Such Object available on this agent at this OID >> Runtime for discovery module 'ports-stack': 0.0380 seconds with 1232 bytes >> SNMP: [1/0.04s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module ports-stack #### Modules status: Global- OS Device Module [ xdsl ] disabled globally. Modules status: Global+ OS Device #### Load disco module entity-physical #### SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUt' '-Pu' '-Os' 'udp:HOSTNAME:161' 'ENTITY-MIB::entPhysicalTable'] entPhysicalTable = No Such Object available on this agent at this OID SNMP query failed. Exit Code: 0 Empty: false Bad String: No Such Object available on this agent at this OID SQL[select * from `entPhysical` where `entPhysical`.`device_id` = ? and `entPhysical`.`device_id` is not null [55] 0.42ms] >> Runtime for discovery module 'entity-physical': 0.0170 seconds with 8072 bytes >> SNMP: [1/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module entity-physical #### Modules status: Global- OS Device Module [ entity-state ] disabled globally. Modules status: Global- OS Device Module [ isis ] disabled globally. Modules status: Global+ OS Device #### Load disco module processors #### No YAML Discovery data. Host Resources: SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'hrProcessorLoad'] hrProcessorLoad = No Such Object available on this agent at this OID Invalid snmp_walk() data = hrProcessorLoad = No Such Object available on this agent at this OID UCD Resources: SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.11.11.0'] 94 Discovered LibreNMS\Device\Processor Array ( [processor_id] => [entPhysicalIndex] => 0 [hrDeviceIndex] => 0 [device_id] => 55 [processor_oid] => .1.3.6.1.4.1.2021.11.11.0 [processor_index] => 0 [processor_type] => ucd-old [processor_usage] => 6 [processor_descr] => CPU [processor_precision] => -1 [processor_perc_warn] => 75 ) .SQL[DELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [] 0.36ms] >> Runtime for discovery module 'processors': 0.0360 seconds with 44984 bytes >> SNMP: [2/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module processors #### Modules status: Global+ OS Device #### Load disco module mempools #### Cache miss for snmpwalk HOST-RESOURCES-MIB::hrStorageTable, grabbing fresh data. SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB:HOST-RESOURCES-TYPES' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Pu' '-Os' 'udp:HOSTNAME:161' 'HOST-RESOURCES-MIB::hrStorageTable'] hrStorageTable = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'memTotalSwap.0' 'memAvailSwap.0' 'memTotalReal.0' 'memAvailReal.0' 'memBuffer.0' 'memCached.0' 'memSysAvail.0'] memTotalSwap.0 = 0 memAvailSwap.0 = 0 memTotalReal.0 = 16395864 memAvailReal.0 = 11434056 memBuffer.0 = 46784 memCached.0 = 1847056 memSysAvail.0 = No Such Object available on this agent at this OID Rejecting Mempool 2 Swap space: Invalid total value 0 x Free memory adjusted by availability calculation: 10.9 GiB -> 12.71 GiB SQL[select * from `mempools` where `mempools`.`device_id` = ? and `mempools`.`device_id` is not null [55] 0.42ms] SQL[update `mempools` set `mempool_used` = ?, `mempool_free` = ? where `mempool_id` = ? [3141599232,13647765504,191] 0.68ms] Updated data: array ( 'mempool_used' => 3141599232.0, 'mempool_free' => 13647765504.0, ) .SQL[update `mempools` set `mempool_used` = ?, `mempool_free` = ? where `mempool_id` = ? [1891385344,14897979392,193] 1.94ms] Updated data: array ( 'mempool_used' => 1891385344.0, 'mempool_free' => 14897979392.0, ) Physical memory (system): 19% 2.93 GiB / 15.64 GiB Memory buffers (buffers): 0% 45.69 MiB / 15.64 GiB Cached memory (cached): 11% 1.76 GiB / 15.64 GiB >> Runtime for discovery module 'mempools': 0.0340 seconds with 89688 bytes >> SNMP: [2/0.03s] MySQL: [3/0.03s] RRD: [0/0.00s] #### Unload disco module mempools #### Modules status: Global+ OS Device #### Load disco module cisco-vrf-lite #### >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with -48 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS Device Module [ cisco-mac-accounting ] disabled globally. Modules status: Global- OS Device Module [ cisco-pw ] disabled globally. Modules status: Global- OS Device Module [ vrf ] disabled globally. Modules status: Global+ OS Device #### Load disco module ospfv3 #### Processes: SQL[select * from `vrf_lite_cisco` where `vrf_lite_cisco`.`device_id` = ? and `vrf_lite_cisco`.`device_id` is not null [55] 0.23ms] SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUt' '-Pu' '-Os' 'udp:HOSTNAME:161' 'OSPFV3-MIB::ospfv3GeneralGroup'] ospfv3GeneralGroup = No Such Object available on this agent at this OID >> Runtime for discovery module 'ospfv3': 0.2730 seconds with 3592 bytes >> SNMP: [1/0.27s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ospfv3 #### Modules status: Global- OS Device Module [ cisco-cef ] disabled globally. Modules status: Global- OS Device Module [ slas ] disabled globally. Modules status: Global- OS Device Module [ cisco-otv ] disabled globally. Modules status: Global- OS Device Module [ cisco-qfp ] disabled globally. Modules status: Global+ OS Device #### Load disco module ipv4-addresses #### SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUt' '-Pu' '-Os' 'udp:HOSTNAME:161' 'IP-MIB::ipAdEntAddr'] ipAdEntAddr[*] = * ipAdEntAddr[*] = * ipAdEntAddr[*] = * ipAdEntAddr[*] = * SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUt' '-Pu' '-Os' 'udp:HOSTNAME:161' 'IP-MIB::ipAdEntIfIndex'] ipAdEntIfIndex[*] = 8388611 ipAdEntIfIndex[*] = 8388610 ipAdEntIfIndex[*] = 8388612 ipAdEntIfIndex[*] = 8388609 SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUt' '-Pu' '-Os' 'udp:HOSTNAME:161' 'IP-MIB::ipAdEntNetMask'] ipAdEntNetMask[*] = * ipAdEntNetMask[*] = * ipAdEntNetMask[*] = * ipAdEntNetMask[*] = * SQL[select `port_id`, `ifIndex` from `ports` where `device_id` = ? [55] 0.39ms] 10.49.49.41 - 31 10.49.49.42 - 31 10.49.49.73 - 30 192.168.149.111 - 32 SQL[select * from `ipv4_networks` where (`ipv4_network` = ? and `context_name` = ?) limit 1 ["10.49.49.40\/31",""] 0.29ms] SQL[select * from `ipv4_networks` where (`ipv4_network` = ? and `context_name` = ?) limit 1 ["10.49.49.42\/31",""] 0.17ms] SQL[select * from `ipv4_networks` where (`ipv4_network` = ? and `context_name` = ?) limit 1 ["10.49.49.72\/30",""] 0.15ms] SQL[select `ipv4_addresses`.*, `ports`.`device_id` as `laravel_through_key` from `ipv4_addresses` inner join `ports` on `ports`.`port_id` = `ipv4_addresses`.`port_id` where `ports`.`device_id` = ? [55] 0.75ms] .... >> Runtime for discovery module 'ipv4-addresses': 0.0540 seconds with 40896 bytes >> SNMP: [3/0.05s] MySQL: [5/0.02s] RRD: [0/0.00s] #### Unload disco module ipv4-addresses #### Modules status: Global+ OS Device #### Load disco module ipv6-addresses #### SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUt' '-Pu' 'udp:HOSTNAME:161' 'IP-MIB::ipAddressTable'] IP-MIB::ipAddressIfIndex[ipv4]["*"] = 8388611 IP-MIB::ipAddressIfIndex[ipv4]["*"] = 8388610 IP-MIB::ipAddressIfIndex[ipv4]["*"] = 8388612 IP-MIB::ipAddressIfIndex[ipv4]["*"] = 8388609 IP-MIB::ipAddressType[ipv4]["*"] = unicast IP-MIB::ipAddressType[ipv4]["*"] = unicast IP-MIB::ipAddressType[ipv4]["*"] = unicast IP-MIB::ipAddressType[ipv4]["*"] = unicast IP-MIB::ipAddressPrefix[ipv4]["*"] = IP-MIB::ipAddressPrefixPrefix[8388611][ipv4][.*.31 IP-MIB::ipAddressPrefix[ipv4]["*"] = IP-MIB::ipAddressPrefixPrefix[8388610][ipv4][.*.31 IP-MIB::ipAddressPrefix[ipv4]["*"] = IP-MIB::ipAddressPrefixPrefix[8388612][ipv4][.*.30 IP-MIB::ipAddressPrefix[ipv4]["*"] = IP-MIB::ipAddressPrefixPrefix[8388609][ipv4][.4294967232.4294967208.4294967189.111.32 IP-MIB::ipAddressOrigin[ipv4]["*"] = manual IP-MIB::ipAddressOrigin[ipv4]["*"] = manual IP-MIB::ipAddressOrigin[ipv4]["*"] = manual IP-MIB::ipAddressOrigin[ipv4]["*"] = manual IP-MIB::ipAddressStatus[ipv4]["*"] = preferred IP-MIB::ipAddressStatus[ipv4]["*"] = preferred IP-MIB::ipAddressStatus[ipv4]["*"] = preferred IP-MIB::ipAddressStatus[ipv4]["*"] = preferred IP-MIB::ipAddressCreated[ipv4]["*"] = 0 IP-MIB::ipAddressCreated[ipv4]["*"] = 0 IP-MIB::ipAddressCreated[ipv4]["*"] = 0 IP-MIB::ipAddressCreated[ipv4]["*"] = 0 IP-MIB::ipAddressLastChanged[ipv4]["*"] = 0 IP-MIB::ipAddressLastChanged[ipv4]["*"] = 0 IP-MIB::ipAddressLastChanged[ipv4]["*"] = 0 IP-MIB::ipAddressLastChanged[ipv4]["*"] = 0 IP-MIB::ipAddressRowStatus[ipv4]["*"] = active IP-MIB::ipAddressRowStatus[ipv4]["*"] = active IP-MIB::ipAddressRowStatus[ipv4]["*"] = active IP-MIB::ipAddressRowStatus[ipv4]["*"] = active IP-MIB::ipAddressStorageType[ipv4]["*"] = permanent IP-MIB::ipAddressStorageType[ipv4]["*"] = permanent IP-MIB::ipAddressStorageType[ipv4]["*"] = permanent IP-MIB::ipAddressStorageType[ipv4]["*"] = permanent SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Pu' 'udp:HOSTNAME:161' 'IPV6-MIB::ipv6AddrPfxLength'] IPV6-MIB::ipv6AddrPfxLength = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Pu' 'udp:HOSTNAME:161' 'IPV6-MIB::ipv6AddrType'] IPV6-MIB::ipv6AddrType = No Such Object available on this agent at this OID SQL[select `ipv6_addresses`.*, `ports`.`device_id` as `laravel_through_key` from `ipv6_addresses` inner join `ports` on `ports`.`port_id` = `ipv6_addresses`.`port_id` where `ports`.`device_id` = ? [55] 0.49ms] >> Runtime for discovery module 'ipv6-addresses': 0.0600 seconds with 74320 bytes >> SNMP: [3/0.06s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv6-addresses #### Modules status: Global+ OS Device #### Load disco module qos #### >> Runtime for discovery module 'qos': 0.0000 seconds with 0 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module qos #### Modules status: Global- OS Device Module [ route ] disabled globally. Modules status: Global+ OS Device #### Load disco module transceivers #### >> Runtime for discovery module 'transceivers': 0.0000 seconds with 0 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module transceivers #### Modules status: Global+ OS Device #### Load disco module sensors #### ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'entPhysicalDescr'] entPhysicalDescr = No Such Object available on this agent at this OID Invalid snmp_walk() data = entPhysicalDescr = No Such Object available on this agent at this OID SQL[select * from `sensors` where `sensors`.`device_id` = ? and `sensors`.`device_id` is not null [55] 0.39ms] Airflow: Ber: Bitrate: Charge: Chromatic_dispersion: Cooling: Count: Current: Dbm: Delay: Eer: Fanspeed: Frequency: Humidity: Load: Loss: Percent: Power: Power_consumed: Power_factor: Pressure: Quality_factor: Runtime: Signal: Snr: State: Temperature: Tv_signal: Voltage: Waterflow: >> Runtime for discovery module 'sensors': 0.0180 seconds with 8032 bytes >> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module sensors #### Modules status: Global+ OS Device #### Load disco module storage #### Cache hit for snmpwalk HOST-RESOURCES-MIB::hrStorageTable SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Pu' 'udp:HOSTNAME:161' 'UCD-SNMP-MIB::dskTable'] UCD-SNMP-MIB::dskTable = No Such Object available on this agent at this OID SQL[select * from `storage` where `storage`.`device_id` = ? and `storage`.`device_id` is not null [55] 0.39ms] >> Runtime for discovery module 'storage': 0.0180 seconds with 3920 bytes >> SNMP: [1/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module storage #### Modules status: Global+ OS Device #### Load disco module hr-device #### SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB:HOST-RESOURCES-TYPES' '-v2c' '-c' 'COMMUNITY' '-OQXUt' '-Pu' '-Os' 'udp:HOSTNAME:161' 'HOST-RESOURCES-MIB::hrProcessorLoad'] hrProcessorLoad = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB:HOST-RESOURCES-TYPES' '-v2c' '-c' 'COMMUNITY' '-OQXUt' '-Pu' '-Os' 'udp:HOSTNAME:161' 'HOST-RESOURCES-MIB::hrDeviceTable'] hrDeviceTable = No Such Object available on this agent at this OID SQL[select * from `hrDevice` where `hrDevice`.`device_id` = ? and `hrDevice`.`device_id` is not null [55] 0.35ms] >> Runtime for discovery module 'hr-device': 0.0350 seconds with 7120 bytes >> SNMP: [2/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module hr-device #### Modules status: Global+ OS Device #### Load disco module discovery-protocols #### LLDP-MIB: SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Pu' '-Os' 'udp:HOSTNAME:161' 'LLDP-MIB::lldpRemTable'] lldpRemTable = No Such Object available on this agent at this OID LLDP-V2-MIB: SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Pu' '-Os' 'udp:HOSTNAME:161' 'LLDP-V2-MIB::lldpV2RemTable'] lldpV2RemTable = No more variables left in this MIB View (It is past the end of the MIB tree) OSPF Discovery: OSPFv3 Discovery: SQL[select distinct `ospfv3NbrAddress`, `device_id` from `ospfv3_nbrs` where `device_id` = ? [55] 0.24ms] SQL[DELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [] 0.26ms] 0 orphaned links deleted >> Runtime for discovery module 'discovery-protocols': 0.0440 seconds with 11424 bytes >> SNMP: [2/0.04s] MySQL: [2/0.01s] RRD: [0/0.00s] #### Unload disco module discovery-protocols #### Modules status: Global+ OS Device #### Load disco module arp-table #### Cache miss for snmpwalk IP-MIB::ipNetToPhysicalPhysAddress, grabbing fresh data. SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Pu' 'udp:HOSTNAME:161' 'IP-MIB::ipNetToPhysicalPhysAddress'] IP-MIB::ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Pu' 'udp:HOSTNAME:161' 'IP-MIB::ipNetToMediaPhysAddress'] IP-MIB::ipNetToMediaPhysAddress = No Such Object available on this agent at this OID SQL[select * from `ipv4_mac` where `ipv4_mac`.`device_id` = ? and `ipv4_mac`.`device_id` is not null [55] 0.35ms] >> Runtime for discovery module 'arp-table': 0.0360 seconds with 8272 bytes >> SNMP: [2/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module arp-table #### Modules status: Global+ OS Device #### Load disco module ipv6-nd #### Cache hit for snmpwalk IP-MIB::ipNetToPhysicalPhysAddress SQL[select * from `ipv6_nd` where `ipv6_nd`.`device_id` = ? and `ipv6_nd`.`device_id` is not null [55] 0.31ms] >> Runtime for discovery module 'ipv6-nd': 0.0010 seconds with 10144 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv6-nd #### Modules status: Global- OS Device Module [ discovery-arp ] disabled globally. Modules status: Global- OS Device Module [ junose-atm-vp ] disabled globally. Modules status: Global+ OS Device #### Load disco module bgp-peers #### SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Pu' 'udp:HOSTNAME:161' 'BGP4-MIB::bgpLocalAs.0'] BGP4-MIB::bgpLocalAs.0 = No Such Object available on this agent at this OID No BGP on hostPeers : SQL[DELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [55,""] 0.3ms] SQL[DELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [55,""] 0.13ms] >> Runtime for discovery module 'bgp-peers': 0.0140 seconds with 1984 bytes >> SNMP: [1/0.01s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module bgp-peers #### Modules status: Global+ OS Device #### Load disco module vlans #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1dBasePortIfIndex'] dot1dBasePortIfIndex = No Such Object available on this agent at this OID Invalid snmp_walk() data = dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1qVlanVersionNumber.0'] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 0.0340 seconds with 880 bytes >> SNMP: [2/0.03s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module vlans #### Modules status: Global- OS Device Module [ vminfo ] disabled globally. Modules status: Global- OS Device Module [ printer-supplies ] disabled globally. Modules status: Global+ OS Device #### Load disco module ucd-diskio #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-DISKIO-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'diskIOEntry'] diskIOEntry = No Such Object available on this agent at this OID Invalid snmp_walk() data = diskIOEntry = No Such Object available on this agent at this OID array ( ) >> Runtime for discovery module 'ucd-diskio': 0.0150 seconds with 792 bytes >> SNMP: [1/0.02s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module ucd-diskio #### Modules status: Global- OS Device Module [ applications ] disabled globally. Modules status: Global+ OS Device #### Load disco module services #### >> Runtime for discovery module 'services': 8.9880 seconds with 0 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module services #### Modules status: Global+ OS Device #### Load disco module stp #### SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Pu' 'udp:HOSTNAME:161' 'BRIDGE-MIB::dot1dStpProtocolSpecification.0'] BRIDGE-MIB::dot1dStpProtocolSpecification.0 = No Such Object available on this agent at this OID Instances: SQL[select * from `stp` where `stp`.`device_id` = ? and `stp`.`device_id` is not null [55] 0.4ms] Ports: SQL[select * from `ports_stp` where `ports_stp`.`device_id` = ? and `ports_stp`.`device_id` is not null [55] 0.37ms] >> Runtime for discovery module 'stp': 0.0150 seconds with 7632 bytes >> SNMP: [1/0.01s] MySQL: [2/0.01s] RRD: [0/0.00s] #### Unload disco module stp #### Modules status: Global+ OS Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 0.0000 seconds with 0 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module ntp #### Modules status: Global- OS Device Module [ loadbalancers ] disabled globally. Modules status: Global- OS Device Module [ mef ] disabled globally. Modules status: Global+ OS Device #### Load disco module wireless #### SQL[select * from `wireless_sensors` where `wireless_sensors`.`device_id` = ? and `wireless_sensors`.`device_id` is not null [55] 0.31ms] >> Runtime for discovery module 'wireless': 0.0030 seconds with 2944 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module wireless #### Modules status: Global+ OS Device #### Load disco module fdb-table #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1qTpFdbPort'] dot1qTpFdbPort = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1dTpFdbPort'] dot1dTpFdbPort = No Such Object available on this agent at this OID >> Runtime for discovery module 'fdb-table': 0.0350 seconds with 736 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module fdb-table #### Modules status: Global+ OS Device #### Load disco module mpls #### >> Runtime for discovery module 'mpls': 0.0000 seconds with 0 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module mpls #### SQL[update `devices` set `last_discovered_timetaken` = ?, `last_discovered` = NOW() where `device_id` = ? [2.037,55] 0.65ms] Discovered in 2.037 seconds ./discovery.php 192.168.149.111 2025-06-23 14:19:15 - 1 devices discovered in 2.206 secs SNMP [37/0.86s]: Snmpget[11/0.14s] Snmpwalk[26/0.73s] SQL [53/0.16s]: Select[27/0.09s] Delete[5/0.01s] Update[21/0.06s] RRD [0/0.00s]: SnmpQuery Cache Performance HOST-RESOURCES-MIB::hrStorageTable cache hits: 1 IP-MIB::ipNetToPhysicalPhysAddress cache hits: 1